Single-component adsorption of poly(1-vinylpyrrolidone)-polystyre

Single-component adsorption of poly(1-vinylpyrrolidone)-polystyrene was on the order BMN 673 of 10(-3) g/g;

with polyamide-epichlorohydrin resin adsorbed on the fiber, the adsorption increased one-order of magnitude to 10(-2) g/g. We believe this significant increase is caused by neutralization of fiber surface charge via polyamide-epichlorohydrin resin, creating a surface more favorable for adsorption and recovery of nonionic species. (C) 2010 Wiley Periodicals, Inc. J Appl Polym Sci 117: 1476-1485, 2010″
“A case of bilateral compound odontomas in the region of the third molars in the maxilla is reported. The differential ARN-509 concentration diagnosis for this case is discussed. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108:e25-e31)”
“Objective-To describe the use of hydropulsion with sterile isotonic buffered ophthalmic solution (ie, eyewash) for the treatment of superficial corneal foreign bodies in veterinary patients and evaluate signalment, clinical findings, and outcomes following the procedure.

Design-Retrospective case series.

Animals-11 dogs, 2 cats, and 2 horses.

Procedures-Medical records were retrospectively reviewed to identify

patients that underwent hydropulsion treatment for a superficial, nonpenetrating corneal foreign body confirmed by ophthalmic examination. Data regarding signalment, reason for evaluation, ocular diagnoses, and treatment were recorded. Hydropulsion was performed

with a 6-mL syringe filled with eyewash solution and a 25-gauge needle with the needle tip removed. Owners and referring veterinarians of patients that did not have a recheck examination recorded were contacted by telephone for follow-up information.

Results-The corneal foreign body was an incidental finding in 3 of 15 patients. The most common clinical signs included blepharospasm, conjunctival hyperemia, and corneal vascularization. Hydropulsion was successful NOV120101 for foreign body removal in all 15 cases. No complications were observed during or following the procedure. In the 9 patients that had a follow-up examination, the cornea tested negative for retention of topically applied fluorescein (with a mean of 6.3 days from treatment to follow-up). At the time of last follow-up examination or telephone follow-up, no patients were reported to have clinical signs of ocular discomfort or corneal opacity associated with the affected site.

Conclusions and Clinical Relevance-In these patients, hydropulsion was easily performed with readily available materials and was successful for the removal of superficial corneal foreign bodies with no adverse effects.

Comments are closed.