“MHC-peptide

multimers containing biotinylated MHC


“MHC-peptide

multimers containing biotinylated MHC-peptide complexes bound to phycoerythrin (PE) streptavidin (SA) Roscovitine datasheet are widely used for analyzing and sorting antigen-specific T cells. Here we describe alternative T cell-staining reagents that are superior to conventional reagents. They are built on reversible chelate complexes of Ni2+-nitrilotriacetic acid (NTA) with oligohistidines. We synthesized biotinylated linear mono-, di-, and tetra-NTA compounds using conventional solid phase peptide chemistry and studied their interaction with HLA-A 0201-peptide complexes containing a His(6), His(12), or 2 x His(6) tag by surface plasmon resonance on SA-coated sensor chips and equilibrium dialysis. The binding avidity increased in the order His(6) < His(12) < 2 x His(6) and NTA(1) < NTA(2) < NTA(4), respectively, depending on the configuration of the NTA moieties and increased to picomolar K-D for the combination of a 2 x His(6) tag and a 2 x Ni2+-NTA(2). We demonstrate

that HLA-A2-2 x His(6)-peptide multimers containing either Ni2+-NTA(4)-biotin and PE-SA- or PE-NTA(4)-stained influenza and Melan A-specific CD8+ T cells equal or better than conventional multimers. Although these complexes were highly stable, find more they very rapidly dissociated in the presence of imidazole, which allowed sorting of bona fide antigen-specific CD8+ T cells without inducing T cell death as well as assessment of HLA-A2-peptide monomer dissociation kinetics on CD8+ T cells.”
“We present a case of multiple schwannomas of the oral floor in a 62-year-old man, which met the

diagnostic criteria of schwannomatosis. (C) 2010 British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.”
“Objectives: The purpose of this study was to test the biomechanical properties of locking and nonlocking plates using one-third tubular and periarticular plate designs in an osteoporotic distal fibula fracture model.Methods: Twenty-four cadaveric specimens, BEZ235 mw whose bone mineral densities were obtained using dual x-ray absorptiometry scans, were tested. The fracture model simulated an OTA 44-B2.1 fracture. The constructs included (1) nonlocking one-third tubular plate, (2) locking one-third tubular plate, (3) nonlocking periarticular plate, and (4) locking periarticular plate. The specimens underwent axial loading followed by torsional loading to failure. Statistical analysis was performed using Kruskal-Wallis testing and further analysis with Mann-Whitney testing.Results: The periarticular plates had greater rotational stiffness compared with the one-third tubular plates (P = 0.04).

Comments are closed.